Load Cell

Load Cell Overview

Load cells measure force/weight to detect object presence, evaluate structural loading, or monitor mechanical stress. The system supports dual load cell configuration.

Hardware Specifications

Parameter

Value

Sensor Count

2 (independent)

Interface

Analog ADC

Measurement

Force (Newtons) / Mass (grams)

Update Rate

Configurable

Data Structure

typedef struct {
    // Raw Reading
    int32_t raw_counts;                 // ADC value from sensor
    
    // Converted Measurements
    float force_newtons;                // Force in Newtons (N)
    float mass_grams;                   // Equivalent mass in grams (g)
    
    // Calibration Parameters
    float scale_newtons_per_count;      // Conversion factor (N/count)
    int32_t tare_offset_counts;         // Zero-load ADC offset
    
    // Status
    bool is_calibrated;                 // Calibration valid flag
} load_cell_data_t;

Initialization

Initialize Load Cells

load_cell_data_t load_cell_data[2];  // Support 2 sensors

for (size_t i = 0; i < 2; i++) {
    load_cell_sensor_init(&load_cell_data[i]);
}

Poll Load Cell Sensor

result_t lc_result = poll_load_cell_sensor(&load_cell_data[0]);

if (lc_result == RESULT_OK) {
    float force = load_cell_data[0].force_newtons;
    float mass = load_cell_data[0].mass_grams;
    int32_t raw = load_cell_data[0].raw_counts;
}

Data Access Functions

// Get force in Newtons
result_t load_cell_get_force_newtons(
    const load_cell_data_t *data,
    float *force_newtons
);

// Get mass in grams (estimated)
result_t load_cell_get_mass_grams(
    const load_cell_data_t *data,
    float *mass_grams
);

// Get raw ADC counts
result_t load_cell_get_raw_counts(
    const load_cell_data_t *data,
    int32_t *raw_counts
);

// Get calibration parameters
result_t load_cell_get_calibration(
    const load_cell_data_t *data,
    float *scale_newtons_per_count,
    int32_t *tare_offset_counts
);

// Verify sensor validity
result_t load_cell_sensor_is_valid(
    const load_cell_data_t *data,
    bool *is_valid
);

Calibration Procedure

Two-Step Calibration

Step 1: Tare (Zero Load)

1. Remove all load from sensor
2. Measure ADC value: ADC_zero
3. Set tare_offset_counts = ADC_zero

Step 2: Span (Known Weight)

1. Place known weight on sensor
2. Measure ADC value: ADC_loaded
3. Know reference force: F_ref (Newtons)

4. Calculate scale:
   scale = (F_ref - 0.0) / (ADC_loaded - ADC_zero)
   
5. Set scale_newtons_per_count = scale

Measurement Formulas

// Raw force calculation
Force = (raw_counts - tare_offset_counts) × scale_newtons_per_count

// Mass conversion (approximate)
Mass_grams = (Force_newtons / 9.81) × 1000
           ≈ Force_newtons × 102.04

Dual Sensor Management

Configuration Example

// Initialize both sensors
for (size_t i = 0; i < 2; i++) {
    load_cell_sensor_init(&load_cell_data[i]);
}

// Poll both in sequence
poll_load_cell_sensor(&load_cell_data[0]);
poll_load_cell_sensor(&load_cell_data[1]);

// Access by index
float load_0 = load_cell_data[0].force_newtons;
float load_1 = load_cell_data[1].force_newtons;

Protobuf Message Format

message SensorBoardLoadCellInfo {
    uint32 sensor_index;         // 0 or 1
    float force_newtons;
    float mass_grams;
    SensorState state;
    LoadCellErrorCode error_code;
}

Unit Conversions

From

To

Factor

Newtons

kilograms-force (kgf)

÷ 9.81

Newtons

pounds-force (lbf)

÷ 4.448

grams

kilograms

÷ 1000

Manual Unit Conversion Example

// Convert to pounds-force
float force_lbf = load_cell_data[0].force_newtons / 4.448f;

// Convert to kilograms
float mass_kg = load_cell_data[0].mass_grams / 1000.0f;

Typical Specifications

Load Cell Type

Max Load

Accuracy

Strain gauge (±50N)

50N

±0.1%

Load cell (±100N)

100N

±0.05%

Heavy duty (±1000N)

1000N

±0.1%

Integration Notes

  • Supports up to 2 independent load cell sensors
  • Hardware-specific ADC implementation
  • Force conversion via linear scaling model
  • Tare offset corrects for sensor mechanical zero
  • Real-time monitoring of structural loads
  • Each sensor maintains separate calibration
  • Independent error reporting per sensor